Is your electric standing desk not working as it should? Start here. Most problems can be solved with a reset, and the code on the handset display tells you what the control box has detected.

Reset instructions

A reset often helps when the desk only moves down, stops in the middle of a movement, shows RST or a flashing code, or is tilted.

  1. 1Clear the area under the desk.
  2. 2Press and hold the down button on the handset until the desk reaches its lowest position. This can take up to 30 seconds.
  3. 3Release the button for a couple of seconds, then press the down button again. The display shows RST when the desk is in reset mode.
  4. 4Keep holding the down button until the desk moves slightly down and then back up. Then release the button.

Important: if the desk starts to tilt during the reset, release the button immediately.

A reset takes less than two minutes and can be repeated if needed.

If the reset does not help

Check that all cables are properly connected and try the reset again. If it still does not work, contact us and tell us the model of your handset.

Tips

Avoid cutting the power while the desk is moving, keep the cables secured and spread the load evenly on the desktop.

Common issues

The desk does not move

Check the wall socket, power cord, handset cable and motor cables. Unplug the desk for 30 seconds and then do a reset. If the desk has been running continuously for more than 2 minutes, let it rest for about 18 minutes (overheating protection). If it still does not move, contact us.

The desk only moves down or only up

The control box has usually lost track of the height after a power cut or a loose plug. Reset the desk and check that there is no excess weight or obstruction.

The display shows an error code

See the table below. If your code is not listed, contact us and tell us the code and the model of your handset.

Memory positions do not work

Positions can be erased by a reset or a power cut, or they may not have been saved. Save them again as described in the handset manual.

The desk is tilted or uneven

Possible causes are columns that are out of sync, an uneven load or an uneven floor. Reset the desk, spread the weight evenly and check the levelling feet and the frame screws. If the desk stays tilted, contact us.

The desk stops and moves back slightly

The anti-collision function has detected an obstacle or resistance. Clear cables and chair armrests out of the way, check the load and make sure the control box is firmly attached. If needed, adjust the sensitivity (see the table below).

The handset display is blank

Check the handset cable, power cord and socket, then unplug the desk for 30 seconds.

Display messages and error codes

Find the message shown on your handset in the table.

RST
Reset required. Follow the reset instructions above.
LOC
The handset is locked. Hold the M button for about 8 seconds until numbers appear. The way to unlock varies by model. Watch the video.
H01
Overheating protection. Let the desk rest for about 18 minutes.
E01 - E06
Overcurrent protection on a motor port (E01 = port M1, E02 = port M2 and so on). Common causes are overload, a column pushing past its end position, or a fault. Reduce the load, clear any obstructions and reset the desk.
E07 / E08
Motor signal error on port M1 or M2. Some models also show E09 (port M3). See the step-by-step guide below.
E13
Connection error between two control boxes. Check the cable, switch the power off for 30 seconds and reset the desk. If the code stays, one of the control boxes may be faulty.
888 or 000
Handset fault. The handset most likely needs to be replaced.
Flashing numbers and the desk does not move
A height limit has been set. Press M and release it, then hold M until 555 is shown. The limit is now removed.
Wrong height shown
Enter reset mode so that the display shows RST. Hold M for 5 seconds, set the correct height with the up and down buttons and finish the reset (the last step of the reset instructions).
Height shown in inches instead of centimetres
Enter reset mode so that the display shows RST. Hold memory button 2 for 5 seconds and select 10.3 for centimetres or 10.4 for inches.
Anti-collision sensitivity
Enter reset mode so that the display shows RST. Hold the up button for 5 seconds and select 10.5 (very sensitive), 10.6 (medium) or 10.7 (less sensitive).

Troubleshooting E07 and E08

Go through the steps in order and stop when the problem is solved.

  1. 1Reset the desk and try to adjust the height. If the code does not return, you do not need to do anything else.
  2. 2If the code returns, unplug the power cord and swap the column cables between ports M1 and M2. Plug the desk in again and reset it. If the code stays the same, the port in the control box is faulty.
  3. 3If the code changes, check whether there is an extension cable between the column and the control box. If there is none, the column motor is faulty. If there is one, the extension cable is the likely fault, and step 4 will confirm it.
  4. 4Move the extension cable to the other column (do not swap the column cables back) and reset the desk. If the code changes again, the extension cable is faulty. If it does not, the column motor is faulty.

Get help

For technical questions you can use the Jiecang AI assistant: aiservice.jiecang.com. For warranty and returns questions, please contact us.

Did not find a solution? Contact us and tell us the model of your handset and the code shown on the display.